Characteristics :

ThermoOil:  M20.195/235.20 [-20°C, +200°C]

Flowrate:  [0-40l/min]

Means of control and measurement :

  • Cryostat Huber : Unistat P510, [-50°c, +250°C], aircooling, Pcryo 5,3kW [0 -250°C], maximum flowrate=119l/min, maximum pressure drop=3bar, etc.
  • 2 Screw-Type Flowmeters: Kracht SVC 10 A1 G1 P1 K2 with displays
  • 2 differential pressure flow transmitters : Rosemount 2051C [0,2,5bars] with communication kit « inspector »
  • 1 power supply 6,6kW (réf. EA-PS 9040-340)
  • Laboratory Power Supply : 0->30V
  • Power Switch
  • National Instruments :
    • réf. PXIe-5170 : PXIe, 100 MHz, 4- or 8-Channel, 14-Bit, Kintex-7 325T FPGA Reconfigurable PXI Oscilloscope
    • réf. PXIe-6345 : PXIe, 80 AI (16-Bit, 500 kS/s), 2 AO, 24 DIO, PXI Multifunction I/O Module
    • PXIe-4353 : PXIe-4353 32-Channel, 24-Bit PXI Temperature Input Module
    • réf. PXIe-7820R : PXI Digital Reconfigurable I/O Module
    • réf. PXIe-1073 : PXI Chassis